๐Ÿ• Recent Shifts โ€” quick switch
Date & Shift
2026-07-22
Day โ€” Team B
TOTAL NDT OK
168
Units
TOTAL HC&FC REJECT
26
Units
H&F REJECTION %
11.66%
of total production
NDT REJECTION %
13.00%
of total production
DOWNTIME (min)
0
min
๐Ÿ“‹
GENERAL INFORMATION
Date:
2026-07-22
Shift:
Day
Supervisor:
Mohammed ALRoshdi
Team:
B
Total Attendance:
16
Total Absent:
5
Was the Lean Meeting conducted?:
Yes
How many attended the lean meeting:
4
โš ๏ธ
SAFETY OBSERVATIONS
NoObservationStatus
1 The site is dusty Low Risk
๐Ÿ”ฅ
FURNACE STATUS
Furnace Mass Received (Ton) Consumed (Ton) Metal Added (Ton) Mass End of Shift (Ton) Remarks
HA
min: 28T
21,620.00 18,260.00 0.00 3,360.00 โ€”
HC
min: 24T
15,620.00 18,380.00 0.00 -2,760.00 โ€”
SWM1 0.00 0.00 0.00 0.00 โ€”
SWM2 0.00 0.00 0.00 0.00 โ€”
๐ŸŒŠ
LAUNDER CONDITION
StageConditionComments
Received Good โ€”
Hand Over Good โ€”
๐Ÿญ
CASTING PRODUCTION
M/C No. Status Mold Type NDT OK HC & FC Reject NDT Reject Total Rejection % H&F Rej % NDT Rej % Remarks
4 Running Smx201-22m7 50 7 9 66 24.2% 10.6% 13.6% โ€”
5 Running RPM666-17 5H 44 4 1 49 10.2% 8.2% 2.0% โ€”
14 Running Smx201-22 M4 44 8 10 62 29.0% 12.9% 16.1% โ€”
16 Running Smx201-22M5 30 7 9 46 34.8% 15.2% 19.6% โ€”
TOTAL PRODUCTION 223 โ€”โ€”โ€”โ€”
TOTAL REJECTION 55 24.7% 11.7% 13.0% โ€”
๐Ÿ”ง
MACHINE BREAKDOWN REPORT
M/CIssueDownTime (min)Action TakenPending ActionResponsibleStatusOdoo Notification
โ€” No breakdowns recorded โ€”
๐Ÿ› ๏ธ
DIE MAINTENANCE PLAN
Die ModelStatusRemarks
640-16 m1-&m2 Completed โ€”
640-15 .4H Completed โ€”
โœ๏ธ Start a New Report