๐Ÿ• Recent Shifts โ€” quick switch
Date & Shift
2026-11-01
Day โ€” Team A
TOTAL NDT OK
154
Units
TOTAL HC&FC REJECT
15
Units
H&F REJECTION %
7.94%
of total production
NDT REJECTION %
10.58%
of total production
DOWNTIME (min)
0
min
๐Ÿ“‹
GENERAL INFORMATION
Date:
2026-11-01
Shift:
Day
Supervisor:
Ahmed Ali
Team:
A
Total Attendance:
17
Total Absent:
3
Was the Lean Meeting conducted?:
No
โš ๏ธ
SAFETY OBSERVATIONS
NoObservationStatus
โ€” No observations recorded โ€”
๐Ÿ”ฅ
FURNACE STATUS
Furnace Mass Received (Ton) Consumed (Ton) Metal Added (Ton) Mass End of Shift (Ton) Remarks
HA
min: 28T
0.00 0.00 0.00 0.00 โ€”
HC
min: 24T
25.38 5.10 0.00 20.28 โ€”
SWM1 23.90 0.00 0.00 23.90 โ€”
SWM2 0.00 0.00 0.00 0.00 โ€”
๐ŸŒŠ
LAUNDER CONDITION
StageConditionComments
Received Good โ€”
Hand Over Good โ€”
๐Ÿญ
CASTING PRODUCTION
M/C No. Status Mold Type NDT OK HC & FC Reject NDT Reject Total Rejection % H&F Rej % NDT Rej % Remarks
6 Running 444-22 6 3 3 12 50.0% 25.0% 25.0% start by450PM
6 Stopped r79-20 9 4 4 17 47.1% 23.5% 23.5% stop at11am
7 Running 222-17 72 5 6 83 13.3% 6.0% 7.2% more gas hols
16 Standby 444-18 0 0 0 0 0.0% 0.0% 0.0% in Oven to be fix in night time
17 Running 777-18" 67 3 7 77 13.0% 3.9% 9.1% more gas hols
TOTAL PRODUCTION 189 โ€”โ€”โ€”โ€”
TOTAL REJECTION 35 18.5% 7.9% 10.6% โ€”
๐Ÿ”ง
MACHINE BREAKDOWN REPORT
M/CIssueDownTime (min)Action TakenPending ActionResponsibleStatusOdoo Notification
โ€” No breakdowns recorded โ€”
๐Ÿ› ๏ธ
DIE MAINTENANCE PLAN
Die ModelStatusRemarks
444-22" Completed full service
444-18 Completed full service
666-18 Completed full service
๐Ÿ“
ADDITIONAL REMARKS

we got issue with gas holes all machine we check degassing found ok we check SG found ok we done some change on parameter after that come ok

โœ๏ธ Start a New Report